Experience with the V-VAS Knee Orthosis
At the recent ISPO World Congress held in Leipzig, Germany, AC(UK) Directors Derek Jones and William Munro, along with consultant orthopaedic surgeon Martin Buchan, revealed preliminary data from a five year follow-up of over a 100 severe OA knee cases managed with the V-VAS Knee orthosis.
This study reports the results of using a custom-made knee orthosis, the V-VAS as an alternative to surgical intervention. You can read more here and download a copy of our poster about the study. The V-VAS was found to be an ethical and effective device with 90% demonstrating significantly improved pain and mobility. UK manufacture and distribution is planned for the near future.
INTRODUCTION:
Various orthosis designs exist for the management of patients with osteoarthritis of the knee. Custom or off-the-shelf unloader knee orthoses are widely used for relieving pain during weight bearing activities in patients with uni-compartmental osteoarthritis. Although these designs can be mechanically successful, patient tolerance may be low due to a higher concentration of pressures being exerted by straps or condylar pads. This is especially so with severe deformity and can limit the duration over which an orthosis can be tolerated.
The authors have applied a new custom orthosis design (V-VASTM) in an experience of over 100 fittings. This design was investigated due to its ability to fine-tune comfort levels at fitting, its light weight and relatively efficient biomechanical design.
METHODS:
The Varum Valgum adjustable stress (V-VAS™) custom knee orthosis is a new concept for treating patients who present with medial or lateral compartmental arthropathies.
Its design incorporates features intended to increase both effectiveness and compliance. Instead of using a narrow frame as seen on most designs, it uses a total contact cuff on the thigh and tibia along with an adjustable, self aligning, polycentric joint system to create four points of pressure instead of three. There is no need for a condylar pad. This results in increased comfort.
The system’s self-aligning, polycentric hinge design, has a means of linearly adjusting the varum or valgum angle (depending on which compartment is affected) without causing mechanical joint binding.
Even with quite severe deformity the joints fit close to the knee without binding.
The two main patient groups selected for the V-VAS were those presenting with valgus /varus deformity of the knee in excess of 10 degrees and medically unfit for surgery (GROUP 1), or those too young to be considered for knee replacement surgery (GROUP 2).
In Group 2, bracing was seen as an earlier option than osteotomy and could be used in conjunction with pain-relieving injection therapy
Patients liked the fact that the design closely followed the profile of the knee without binding. Each patient was assessed radiographically and a custom cast made of the knee. Partial correction of deformity by the orthotist during cast taking was found to be important in minimising user discomfort. The patient’s perception of pain was used as an indicator of the optimum position during cast taking. It is likely that by demonstrating that pain relief could be achieved during casting, the patients expectations of the brace were raised.
At the fitting stage, the design of the orthotic joint was such that fine adjustments of the amount of offloading were possible. Immediate feedback on pain relief was a very positive aspect of the design. By encouraging the patient to walk up and down stairs ar the fitting stage, the orthotist was able to fine tune the brace performance without the need to remove and reapply.
Radiological assessment before and after use and the decrease in pain on movement were the primary methods of measurement of clinical effectiveness.
RESULTS:
Due to the age range it was important the brace was simple to apply, lightweight and neat in appearance as a high level of compliance was important.
The aim of the bracing strategy was to reduce as much as possible the pain levels and where appropriate, increase levels of mobility.
Group 1- All patients were asked after 6 weeks if they would willingly return the device - All refused.
All patients reported reduction in their pain by 50-70% using a simple 1-10 visual-analogue pain scale. Over 50% reported an increase in mobility in terms of their day to day tasks.
Based on their individual experience, patients had a further 5cm distraction added at this point. In all cases the patients reported that the quality of life outcomes exceeded their expectations.
Group 2 - One patient found the brace difficult to use due to a hypersensitivity following trauma and derived little or no benefit. ?
One patient had initial benefit, reporting 50% pain reduction, however went on to elect for surgery . The remainder reported reduction in pain by 50-70%. They were not willing to go without their brace. Mobility was improved with around 10% returning to some form of activity such as the gym or hill walking. Two patients who were clinically obese reported migration of the brace in-situ as a problem.?
CONCLUSION:
The V-VAS was found to be an ethical and effective device in both study groups with 90% demonstrating significantly improved pain and mobility
REFERENCES:
Finger S, Paulos LE. Clinical and Biomechanical Evaluation of the Unloading Brace. Journal of Knee Surgery 2002; 15: 155-159.
Pollo FE, Otis JC, Backus SI, Warren RF, Wickiewicz TL. Reduction of Medial Compartment Loads with Valgus Bracing of the Osteoarthritic Knee. The American Journal of Sports Medicine 2002; 30:3: 414-421
Article reference
V-VAS Study Poster - ISPO 2010 (3.96 MB 2010-05-28 16:51:46)
Management of Severe OA of the Knee Using a V-VAS™ Customised Off-Loading Knee Orthosis
Munro, W. A - Dip OTC MBAPO - Orthotist - Anatomical Concepts (UK) Ltd, Scotland
Buchan, M - MB ChB, FRCSEd, FRCS(Orth) - Consultant Orthopaedic Surgeon, Inverclyde Hospital, Scotland
Jones D. Ph.D, MBA - Bioengineer - Anatomical Concepts (UK) Ltd, Scotland
Sample Case ( MD - 47yrs )
History
- 1985 left knee arthroscopy & open medial menisectomy
- 1995 repeat arthroscopy shows complete loss of medial chondral surface
- 2005 right knee arthroscopy - bone on bone contact. Both knees moderate PFJ and lateral compartment chondral loss.
Examination
- Bilateral clinical varus >20 degrees
- Both knees lack 5 degrees full extension
- Moderate effusion right knee only
- Severe pain and swelling right knee
Observations
- Too young for joint replacement
- Too severe for chondral resurfacing
- Too advanced for high tibial osteotomy
- May be suitable for Benjamin’s double osteotomy
Interpretation of Outcomes
- Brace initially used 2 - 4 hours per day
- Now used during working day
- Excellent reduction in pain and swelling of right knee
- Weight-bearing Xray
- No brace 11 deg Varus
- With brace 4 deg Varus
Contact Us
Anatomical Concepts (UK) Ltd
8-10 Dunrobin Court
Clydebank Business Park
Clydebank,
Scotland
T: +44(0)141-952-2323
F: +44(0)141-952-3434
Registered in Scotland
No SC162409
Directors
Derek Jones
William Munro
Kenneth Munro
William DeToro
Our Web Sites
Exercise technology for Spinal Cord Injury, MS and Stroke
Tailwind recovers Arm Movement following a Stroke
Rehacom.co.uk
European Leader for Cognitive Rehabilitation
Anatomicalconcepts.com
Home of the PRAFO and the V-VAS in the UK
On-LIne Publishing
Catalogue Preview
-
Click to open image!
Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
- Click to open image! Click to open image!
Orthotic Products
-
650 PRAFO lateral view
650 PRAFO lateral view
- 650 PRAFO frontal view 650 PRAFO frontal view
- 650 PRAFO posterior view 650 PRAFO posterior view
- 650 PRAFO oblique view 650 PRAFO oblique view
- PRAFO APU lateral view PRAFO APU lateral view
- PRAFO APU oblique view PRAFO APU oblique view
- PRAFO APU posterior view PRAFO APU posterior view
- PRAFO Dual Action Pad & Strap Kit PRAFO Dual Action Pad & Strap Kit
- PRAFO Dual Action Pad & Strap Kit PRAFO Dual Action Pad & Strap Kit
- PRAFO Dual Action Posterior view PRAFO Dual Action Posterior view
- PRAFO Dual Action Lateral view PRAFO Dual Action Lateral view
- PRAFO APU - Kodel Liner PRAFO APU - Kodel Liner
- PRAFO APU - Posterior view PRAFO APU - Posterior view
- V-VAS Custom Knee Orthosis V-VAS Custom Knee Orthosis
- V-VAS Custom Knee Orthosis V-VAS Custom Knee Orthosis
- KMO-VV Knee Management Orthosis KMO-VV Knee Management Orthosis
- KMO - VV KMO - VV
- KMO - VV - Posterior view KMO - VV - Posterior view
- KMO - VV - Close up KMO - VV - Close up
- PRAFO section for Evaluation KAFO PRAFO section for Evaluation KAFO
- Action view of PRAFO DualAction Action view of PRAFO DualAction
- Action Sequence Action Sequence